12 Volt - Amps: Amps vs. Wire Gauge - Choosing the Right Wire Size
Maximum current (amps) in a 12V electrical circuit vs. size (AWG) and length of wire. For a 12V system, the maximum voltage drop should be less than 0.36V (3% of 12V).
Wire Gauge Design Procedure
- Calculate total length of wire from source to device and back again
- Determine amount of current in wire
- Determine correct wire gauge in the intersection of amps and feet
Important Notes
- Voltage Drop: Wire size is based on 3% (0.36V) voltage drop in a 12 Volt circuit
- Safety: Failure to use an adequate size may result in a fire. Always secure electric wires with fuses
- Oversizing: Always oversize wires if voltage drop is critical
- Conversion: 1 ft (foot) = 0.3048 m
Examples
- A 12V gauge #6 (13.3 mm²) cable with length 15m can handle approximately 15 amps
- A 12V gauge #10 (5.26 mm²) cable with length 15m can handle approximately 5 amps