Specific heat (C) is the amount of heat required to change the temperature of a mass unit of a substance by one degree. This tool provides isobaric specific heat (Cp) values for hydrogen gas (H2) at temperatures ranging from 175 to 6000 K. Isobaric specific heat is used for substances in constant pressure systems.

Temperature - T - (K)Specific Heat - cp - (kJ/kgK)
17513.12
20013.53
22513.83
25014.05
27514.2
30014.31
32514.38
35014.43
37514.46
40014.48
45014.5
50014.51
55014.53
60014.55
65014.57
70014.6
75014.65
80014.71
85014.77
90014.83
95014.9
100014.98
105015.06
110015.15
115015.25
120015.34
125015.44
130015.54
135015.65
140015.77
150016.02
160016.23
170016.44
180016.64
190016.83
200017.01
210017.18
220017.35
230017.5
240017.65
250017.8
260017.93
270018.06
280018.17
290018.28
300018.39
350018.91
400019.39
450019.83
500020.23
550020.61
600020.96