Meter TypeDischarge Coeff (cd)RangeabilityPressure LossAccuracyUpstream Pipe LengthViscosity EffectRelative Cost
Orifice Plate0.604:1Medium2-4% FS10-30DHighLow
Venturi Meter0.9754:1Low1% FR5-20DHighMedium
Nozzle (ISA 1932)0.95-0.9954:1Medium1-2% FR10-30DHighMedium
Diameter Ratio (d)Re=10⁴Re=10⁵Re=10⁶Re=10⁷
0.20.600.5950.5940.594
0.40.610.6030.5980.598
0.50.620.6080.6030.603
0.60.630.610.6080.608
0.70.640.6140.6090.609
Orifice Diameter (mm)Kv (m³/h)
0.80.02
1.20.05
1.60.08
2.40.17
3.20.26
3.60.31
4.80.45
6.40.60
81.5
91.7
133
164
184.5
196.5
2511
3215
3822
5141
6451
7686
8099
100150
125264
150383