Steam Tracing Pipe Lines

Determines the appropriate number of 1/2 inch (15 mm) steam tracers needed for pipe lines based on pipe size and temperature maintenance requirements.

Calculator

Inputs

Results

Number of 1/2" (15 mm) Steam Tracers-- tracers
Pipe Size (inch)Frost Protection (<75°F / 25°C)Keep Fluid (<150°F / 65°C)Keep Fluid (<300°F / 150°C)
1111
1.5112
2112
3113
4123
6223
8223
12236
16238
202310

Key Information

  • Standard Tracer Size: 1/2 inch (15 mm) diameter pipes
  • Installation: Steam tracers must be stripped to the lower part of process pipes as heat moves upward
  • Applicable Conditions: Normal insulated pipes in normal surrounding conditions
  • Conversion: 1 inch = 25.4 mm

Example

For a 4 inch transport system carrying vegetable oil with solidification temperature at 40°C (104°F), two 1/2 inch steam tracing pipes are appropriate.