WABT - Weighted Average Bed Temperature

Calculate the Weighted Average Bed Temperature (WABT) for adiabatic reactors with one or multiple catalyst beds. WABT provides a single representative temperature value that accounts for temperature profiles across the reactor and is weighted by catalyst mass distribution.

Reactor/BedInlet Temperature (°C)Outlet Temperature (°C)Catalyst Mass (kg)Weight Fraction
Reactor 135039599000.18
Reactor 2370390240000.42
Reactor 3385395225000.4
WABT - Weighted Average Bed Temperature | MEPKit Engineering Tools | MEPKit